Project Details

HIDE BEFORE CONVERTING

Project name

PVX Mounting System

Building and Environment Data

Building height (m)

Largest side of building width or length (m)

Heigt of roof parapet (m)

Type of roofing material

Bitumen

Country

Wind area

Terrain category

Application Data

Type of application

Roof zone

Brand of application

Article number of application

INPUT

Height of application (m)

Widht of application (m)*

Weight of application (kg/m)

Page: 1/3

*For widths exceeding 300 mm, a minimum of two supports is required. Add one additional support for every extra 100 mm of width beyond 300 mm. Additional supports may be used for widths ≤ 300 mm if preferred.

Please specify how many supports are placed side-by-side.

When a mounting rail is used between the supports, what is its weight (kg/m)

Cover included?

Article number of cover

INPUT

Weight of cover (kg/m)

Tubes?

INPUT

Diameter of tube(s) (m)

Weight of tube (kg/m)

Percentage (%) filled with cables

Support spacing

Prefferd support spacing

Result

Page: 2/3

Required number of units

What is the total cable route length (m)?

How much extra (%) for corners?

Type of mounting system:

Support spacing (m):

Required quantity:

Date:

Version number:

3.0

Disclaimers:

This tool is intended to assist in calculating the supp spacing. Although we aim for accuracy, we make no guarantees regarding the completeness, correctness, or timeliness of the results.

Users are solely responsible for providing accurate input to ensure valid results.

We accept no liability for any decisions made based on the results of this tool, or for any direct or indirect damages resulting from its use

The selection of 'brand of application' is provided solely for user convenience. No brand preference, endorsement, or affiliation is implied or intended by PVX Mounting Systems.

Page: 3/3

Project Details

Project name

PVX Mounting System

Application Data

Type of application

How will the cable route be placed?

If horizontal: What is the distance measured from the cable route to the ridge (highest point) of the roof?

Country

Wind area

Terrain category

Type of roofing material

If you choose 'Other', please specify:

Result:

Support spacing

Required number of units

What is the total cable route length (m)?

How much extra (%) for corners?

Type of mounting system:

Support spacing:

Minimum required quantity:

Maximum required quantity:

Date:

Version number:

3.0

Disclaimers:

This tool is intended to assist in calculating the supp spacing. Although we aim for accuracy, we make no guarantees regarding the completeness, correctness, or timeliness of the results.

Users are solely responsible for providing accurate input to ensure valid results.

We accept no liability for any decisions made based on the results of this tool, or for any direct or indirect damages resulting from its use

The selection of 'brand of application' is provided solely for user convenience. No brand preference, endorsement, or affiliation is implied or intended by PVX Mounting Systems.

Page: 1/1

Calculator Roof Zone

Project name:

Enter the fields below to calculate the roof zone of your project:

Building length (m)

Buliding widht (m)

Building hight (m)

Distance from cable route to roof edge (m)

BEREKENING

e:

DEZE gebruikien; dit is e

F-zone lengte

e/4

F-zone breedte

e/10

F-zone hoek

diagonaal naar hoek

G-zone lengte

hangt van lengte gebouw af

G-zone breedte

e/10

ZONE

If the zone above is 'F/G', complete the field below to determine whether it is 'F' or 'G'

Distance from cable route to corner (m)

ZONE

Date:

Version number:

3.0

page 1/1